Axial cable outlet, measuring range up to 15 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex-approval
VEGAPULS C 21 is the ideal sensor for non-contact level measurement in simple applications where a high degree of protection is required. It is particularly suitable for use in water treatment, pumping stations and rain overflow basins, for flow measurement in open channels and level monitoring.
| Technical Specification | |
| Measuring range - Distance | 15m | 
| Process temperature | -40 ... 80°C | 
| Process pressure | -1 ... 3 bar | 
| Accuracy | ± 2 mm | 
| Materials, wetted parts | PVDF | 
| Threaded connection | G1½ / G1, 1½ NPT / 1 NPT, R1½ / R1 | 
| Seal Material | FKM | 
| Protection rating | IP66/IP68 (3 bar), Type 6P | 
| Output | 
 | 
| Ambient temperature | -40 ... 80°C | 
| Display & adjustment | 
 | 
		Measuring range - Distance:
		15 m
		Process Temperature:
		-40 ... 80 °C
		Process Pressure:
		-1 ... 3 bar
		Accuracy:
		± 2 mm
		Frequency:
		80 GHz
		Beam angle:
		8°
		Materials, wetted parts:
		PVDF
		Threaded connection:
		G1 / G1, 1 NPT / 1 NPT, R1 / R1
		Seal Material:
		FKM
Protection rating: IP66/IP68 (3 bar), Type 6P
		Output:
		- 4 ... 20mA/HART
		- Modbus
		- SDI-12
		Ambient temperature:
		-40 ... 80 °C
		Approvals:
		- ATEX / Europe
		-EAC (GOST) / Russia
		- IEC / worldwide
		- NEPSI / China
		- INMETRO / Brazil
		- CCOE / India
		- KTL Korea
		- CSA / USA and Canada
		- FM / USA and Candada
		- TIIS / Japan
		Explosion Protection:
		- Intrinsic safety ''i''
		- Dust explosion protection through housing ''t''
		- Encapsulation ''m''
		Ship Approval:
		- ABS
		- CCS
		- NK
		- RINA
		Display & adjustment:
		- PC, PACTware and DTM