The extended selection of process fittings and materials allows use in extreme temperature and pressure ranges.
The VEGAPULS 66 is a sensor for continuous level measurement of liquids under arduous process conditions. It is suitable for applications in storage tanks, process vessels or standpipes. The VEGAPULS 66 can be used universally thanks to different antenna versions.
Technical Specifications | |
Measuring range - Distance | 35 m |
Process temperature | -60 ... 400 °C |
Process pressure | -1 ... 160 bar |
Accuracy | ± 8 mm |
Frequency | 6 GHz |
Beam angle | ≥ 14° |
Version | Horn antenna of 316L or enamel or standpipe 2'' of 316L |
Flange connection | ≥ DN50, ≥ 2'' |
Housing material | Plastic, Aluminium, Stainless steel |
Output | 4 … 20 mA/HART, Profibus PA, Foundation Fieldbus |
Approvals | ATEX, CSA, FM, EAC (GOST), IEC, KOSHA, NEPSI, UKR Sepro, Explosion protection, Ship, Overfill protection, SIL2 |
Display & adjustment | PLICSCOM, PACTware, VEGADIS 81, VEGADIS 82 |